FEED WATER PARAMETERS :
• Max. temperature 85° F.
• Max. pressure between 40 ~ 80 psi.
• Max. TDS 2,000 ppm.
• Max. Iron tolerance 0.5 ppm.
• Hydrogen sulfide must be removed.
• Silica tolerance can not be higher than 125 ppm in the
concentrate stream.Antiscalant should be considered for any
levels over 75 ppm.
•Turbidity should be removed.
• Hardness must be removed.
OPERATING PARAMETERS :
• Max. operating pressure 200 psi.
• Water recovery up to 60% but not recommended to adjust higher
than 50%.
• pH range 3-11.
• Flow rates are determined by the membrane mfg’s testing
criteria of 1 ,500 ppm NaCI solution, 77°F water temperature,
225 psi at 10 ~ 15% recovery. Actual flow rates may vary
depending on the pretreatment, water conditions, system volumn,
membrane array and operation pressure. |